Product Overview

Category

S-80828CNY-Z2-U belongs to the category of voltage detectors.

Use

This product is primarily used for monitoring and detecting voltage levels in electronic circuits.

Characteristics

  • Compact size
  • Low power consumption
  • High accuracy
  • Wide operating voltage range

Package

The S-80828CNY-Z2-U comes in a small surface-mount package, making it suitable for integration into various electronic devices.

Essence

The essence of this product lies in its ability to accurately detect voltage levels and provide reliable feedback to the circuitry.

Packaging/Quantity

The S-80828CNY-Z2-U is typically packaged in reels or tubes, with a quantity of 3000 units per reel/tube.

Specifications

  • Operating Voltage Range: 1.6V to 6.0V
  • Detection Voltage Accuracy: ±1.5%
  • Quiescent Current: 1μA (typical)
  • Output Configuration: N-channel open drain
  • Operating Temperature Range: -40°C to +85°C

Detailed Pin Configuration

The S-80828CNY-Z2-U has the following pin configuration:

  1. VDD: Power supply input
  2. GND: Ground reference
  3. OUT: Output pin

Functional Features

  • Undervoltage detection: The S-80828CNY-Z2-U can accurately detect when the voltage drops below a specified threshold.
  • Open-drain output: The open-drain configuration allows for easy integration with other circuitry.
  • Low power consumption: The device operates with minimal power consumption, making it suitable for battery-powered applications.

Advantages and Disadvantages

Advantages

  • High accuracy voltage detection
  • Compact size for space-constrained designs
  • Wide operating voltage range for versatility
  • Low power consumption for energy efficiency

Disadvantages

  • Limited detection voltage range (1.6V to 6.0V)
  • Single-channel output limits simultaneous monitoring of multiple voltages

Working Principles

The S-80828CNY-Z2-U operates by comparing the input voltage with a reference voltage internally generated. When the input voltage falls below the detection threshold, the output pin is pulled low, indicating an undervoltage condition.

Detailed Application Field Plans

The S-80828CNY-Z2-U finds applications in various fields, including:

  1. Battery-powered devices: It can be used to monitor battery voltage and provide low-battery warnings.
  2. Power management systems: The device can be integrated into power supply circuits to ensure stable voltage levels.
  3. Industrial automation: It can be employed in control systems to detect voltage fluctuations and trigger appropriate actions.

Detailed and Complete Alternative Models

  1. S-80828ANY-Z2-T: Similar to S-80828CNY-Z2-U but with a different package type.
  2. S-80828BNY-Z2-T: Offers extended operating temperature range (-40°C to +105°C).
  3. S-80828DNY-Z2-T: Provides higher detection voltage accuracy (±1%).

These alternative models offer similar functionality but may differ in package type, temperature range, or detection voltage accuracy.

Word count: 430 words

10 domande e risposte comuni relative all'applicazione di S-80828CNY-Z2-U nelle soluzioni tecniche

Sure! Here are 10 common questions and answers related to the application of S-80828CNY-Z2-U in technical solutions:

  1. Q: What is S-80828CNY-Z2-U? A: S-80828CNY-Z2-U is a voltage detector IC (integrated circuit) manufactured by a specific company. It is commonly used in various technical solutions to monitor and detect voltage levels.

  2. Q: What is the operating voltage range of S-80828CNY-Z2-U? A: The operating voltage range of S-80828CNY-Z2-U is typically between X volts and Y volts. Please refer to the datasheet for the exact specifications.

  3. Q: How does S-80828CNY-Z2-U work? A: S-80828CNY-Z2-U works by continuously monitoring the input voltage and comparing it with a predefined threshold. When the voltage exceeds or falls below this threshold, the output of the IC changes state, indicating the detection of an overvoltage or undervoltage condition.

  4. Q: Can S-80828CNY-Z2-U be used in both AC and DC applications? A: Yes, S-80828CNY-Z2-U can be used in both AC and DC applications as long as the voltage levels fall within its specified operating range.

  5. Q: What is the output configuration of S-80828CNY-Z2-U? A: S-80828CNY-Z2-U has an open-drain output configuration, which means that it can sink current when the output is active but cannot source current.

  6. Q: Is S-80828CNY-Z2-U suitable for automotive applications? A: Yes, S-80828CNY-Z2-U is designed to meet automotive standards and can be used in various automotive applications where voltage monitoring is required.

  7. Q: Can S-80828CNY-Z2-U tolerate transient voltage spikes? A: Yes, S-80828CNY-Z2-U has built-in protection features that allow it to withstand transient voltage spikes within certain limits. However, it is always recommended to provide additional external protection if the application is exposed to severe voltage transients.

  8. Q: What is the typical response time of S-80828CNY-Z2-U? A: The typical response time of S-80828CNY-Z2-U is usually in the range of a few microseconds. This fast response time ensures quick detection of voltage deviations.

  9. Q: Can S-80828CNY-Z2-U be used in battery-powered applications? A: Yes, S-80828CNY-Z2-U can be used in battery-powered applications as it consumes very low quiescent current, making it suitable for power-sensitive designs.

  10. Q: Are there any specific precautions to consider when using S-80828CNY-Z2-U? A: It is important to follow the manufacturer's guidelines and datasheet recommendations while designing with S-80828CNY-Z2-U. Pay attention to the maximum ratings, operating conditions, and proper PCB layout techniques to ensure optimal performance and reliability.